Hicom 150 E Office Rel.1.0 Service Manual - 3.2 Central boards
Voltage range: 88VAC - 264VAC; 50Hz - 60Hz
Power consumption: 39W
Interfaces
Figure 3-5 PSUF interfaces (S30122-K5658-xxx)
Caution
System voltage activation/deactivation is basically performed by inserting or
removing the power plug.

3.2.10 PSUI

Introduction
One PSUI power supply module is used for each cabinet in the Hicom 150 E OfficePro. Two different
PSUIs with the same function are used as a result of production processes. A cumulative LED
indicates the presence of all of the necessary secondary voltages. A PSUI must always be replaced if it
fails. A replacement of fuses within the device by a service technician is not permitted.
The PSUI is used in all national variants. The ring frequency and ring voltage of the integrated ring
generator can be adjusted as required (country-specific).
The two PSUIs are identical on a technical level but differ slightly on a mechanical level (position of
the ring current switch). The two PSUIs are fully compatible.
Part numbers of the two PSUIs
S30122-K5083-L301
S30122-K5083-X301
Technical data
Voltage range: 88 VAC - 264 VAC
Power consumption max. 350 W
Nominal frequency: 50 / 60 Hz (tolerance 47 - 63 Hz)
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_31.htm (9 of 20) [06/04/2000 13:03:00]
(Figure
3-6)
(Figure
3-7)