Hicom 150 E Office Rel.1.0 Service Manual - 8.31 UCD - Universal Call Distribution
11.
# 2
12.
*3
13.
*4
14.
F7
Group Options - queue timers (31 2 2)
Each queue device (total of 7 per UCD group) has its own queue timer
(1-20).
Default queue time entry: 1 = 30s, maximum: 20 = 6 min
Note: no times should be programmed for announcements.
Programming with Hicom Assistant T
Step
Entry
1.
31-2-2
2.
3.
*2
4.
#2
5.
*3
6.
F7
Group Options - call cycles (31 2 3)
The call cycles are set under Group Options.
A distinction is made between primary and secondary cycles and the call cycle in Call
Management.
The call cycles in Call Management are changed accordingly.
Programming with Hicom Assistant T
Step
Entry
1.
31-2-3
2.
1
3.
*4
4.
*5
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_831.htm (4 of 7) [06/04/2000 13:14:19]
Select 2nd UCD group and confirm
Assign Announcement device 3
Assign Announcement device 4
Return to Group Options submenu
Change queue timers (1st UCD group)
Scroll to 2nd Mbr (1st UCD group)
Enter 2 (=60s)
Change queue timers (2nd UCD group)
Scroll to 2nd Mbr (2nd UCD group) 3=90s and confirm Grp 1, Mbr 2: 3
Return to Group Options submenu
Select UCD group and change call cycles
Change to Primary cycle
Change the primary cycle
Scroll to 2nd UCD group and change the default value Grp 2: 5
Action
Action
Grp 2, Mbr 1: Device 1
Grp 2, Mbr 1: Device 3
Grp 2, Mbr 2: Device 4
313 Group Options
Display
Grp 1, Mbr 1: 1
Grp 1, Mbr 2: 1
Grp 1, Mbr 2: 2
Grp 2, Mbr 1: 1
313 Group Options
Display
Call cycles
Grp 1: 3
Grp 1: 4