EHTR—Extended Hold Time on Read
When this bit is set, it adds one clock cycle after a read from the current bank and any CPU
write or read to a different bank.
0 = Timing is defined by the memory controller.
1 = Extended hold time is defined on the current read access.
Bit 31—Reserved
This bit is reserved and must be set to 0.
15.3.1.3 MEMORY STATUS REGISTER. The memory status (MSTAT) register reports
parity and write-protect errors encountered during an external bus access initiated by the
memory controller. To clear a specific bit, write a one to it (writing zero has no effect).
MSTAT
BIT
0
1
2
FIELD
PER0
PER1
PER2
RESET
0
0
0
R/W
R/W
R/W
R/W
ADDR
PER0—Parity Error Bank 0
When this bit is set it indicates that a parity error was detected during a Bank 0 read cycle
initiated by the memory controller.
PER1—Parity Error Bank 1
When this bit is set it indicates that a parity error was detected during a Bank 1 read cycle
initiated by the memory controller.
PER2—Parity Error Bank 2
When this bit is set it indicates that a parity error was detected during a Bank 2 read cycle
initiated by the memory controller.
PER3—Parity Error Bank 3
When this bit is set it indicates that a parity error was detected during a Bank 3 read cycle
initiated by the memory controller.
PER4—Parity Error Bank 4
When this bit is set it indicates that a parity error was detected during a Bank 4 read cycle
initiated by the memory controller.
PER5—Parity Error Bank 5
When this bit is set it indicates that a parity error was detected during a Bank 5 read cycle
initiated by the memory controller.
MOTOROLA
3
4
5
6
7
PER3
PER4
PER5
PER6
PER7
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
(IMMR & 0xFFFF0000) + 0x178
MPC823e REFERENCE MANUAL
8
9
10
11
12
WPER
RESERVED
0
R/W
R/W
Memory Controller
13
14
15
0
15-15