Serial port
(config)>serial port1 logging type value
(config)>
where value is one of:
n
n
n
n
e. Log the time at which date was received or transmitted:
(config)>serial port1 logging hex true
(config)>
f. Log data as hexadecimal values:
(config)>serial port1 logging timestamp true
(config)>
17. Save the configuration and apply the change
(config)> save
Configuration saved.
>
18. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure Application mode

Application mode provides access to the serial device from Python applications. See
port
for information about creating serial ports in Application mode.
To change the configuration to match the serial configuration of the device to which you want to
connect:
Web
Log into the TX40 WebUI as a user with full Admin access rights.
1. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.