Configure Application Mode - Digi LR54 User Manual

Hide thumbs Also See for LR54:
Table of Contents

Advertisement

Serial port
vi. (Optional) Enable Multicast DNS (mDNS):
16. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
17. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure Application mode

Application mode provides access to the serial device from Python applications.
To change the configuration to match the serial configuration of the device to which you want to
connect:
  Web
1. Log into the LR54 WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.
Note
You can also configure the serial port by using Device Configuration > Serial. Changes
made by using either Device Configuration or Serial Configuration will be reflected in both.
LR54 User Guide
ipsec
loopback
setup
(config)>
Repeat this step to include additional firewall zones.
(config)>serial port1 service telnet mdns enable true
(config)>
Configure Application mode
232

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tx64

Table of Contents