System administration

Configure power delays for power ignition sensor

By default, the TX40 device automatically powers on when it detects power on the ignition sensor,
and powers off when it detects that there is no power on the ignition sensor, and there is no delay for
either power on or power off based on the power ignition sensor.
You can configure delays for powering on or off the system based on the state of the ignition sensor.
You can also temporarily override the configured delay to allow for one-time maintenance activities
(such as a firmware update) to occur after the ignition is switched off. See
power delay
for more information.
Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in
device.
b. Click the Device ID.
c. Click Settings.
d. Click to expand Config.
Local Web UI:
a. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click System > Power > Ignition sense control.
4. For Ignition power on delay, type the amount of time to wait to power on the device, after
the device detects that there is power on the ignition sensor.
Allowed values are any number of hours, minutes, or seconds, and take the format number
{h|m|s}.
For example, to set Ignition power on delay to ten minutes, enter 10m or 600s.
The default is 0s, meaning that there is no power on delay.
5. For Ignition power off delay, type the amount of time to wait to power off the device, after
the device detects that there is no longer power on the ignition sensor.
Allowed values are any number of hours, minutes, or seconds, and take the format number
{h|m|s}.
For example, to set Ignition power off delay to ten minutes, enter 10m or 600s.
The default is 0s, meaning that there is no power off delay.
6. Click Apply to save the configuration and apply the change.