Serial port
14. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
15. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure Application mode

Application mode provides access to the serial device from Python applications.
To change the configuration to match the serial configuration of the device to which you want to
connect:
  WebUI
1. Log into the Connect EZ WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.
Note
You can also configure the serial port by using Device Configuration > Serial. Changes
made by using either Device Configuration or Serial Configuration will be reflected in both.
3. Click the name of the port that you want to configure.
The serial port is enabled by default. To disable, toggle off Enable.
4. For Mode, select Application. The default is Login.
5. (Optional) For Label, enter a label that will be used when referring to this port.
6. Enable Altpin to use the Altpin feature. Altpin is disabled by default.
This feature should be enabled when you are using a modem and an 8-pin cable and you need
CD (Carrier Detect). When enabled, the DTR on pin 1 drives DCD.