Services
different buses that have the same Modbus address of 10, you can create two clients on
the gateway:
n
n
i. Repeat the above instructions for additional clients.
6. Save the configuration and apply the change
(config)> save
Configuration saved.
>
7. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Show Modbus gateway status and statistics

You can view status and statistics about location information from either the WebUI or the command
line.
Web
Log into the TX40 WebUI as a user with full Admin access rights.
1. On the menu, select Status > Modbus Gateway.
The Modbus Gateway page appears.
Statistics related to the Modbus gateway server are displayed. If the message Server
connections not available is displayed, this indicates that there are no connected clients.
To view information about Modbus gateway clients, click Clients.
n
To view statistics that are common to both the clients and server, click Common
n
Statistics.
To view configuration details about the gateway, click the  (configuration) icon in the
n
upper right of the gateway's status pane.
Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the TX40
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
TX40 User Guide
Client one:
filter set to 10.
l
This will configure the gateway to deliver all messages that have the Modbus server
address of 10 to this device.
Client two:
filter set to 20.
l
adjust_server_address set to 10.
l
This will configure the gateway to deliver all messages that have the Modbus server
address address of 20 to the device with address 10.
Modbus gateway
721