Download Print this page

Allied Telesis IE340 Series Command Reference Manual page 335

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

P
C
C
LUGGABLES AND
ABLING
OMMANDS
-
FIBER
MONITORING ACTION
To set the device to stop shutting down the port if port1.0.1 or port1.0.4 receive
reduced power, use the commands:
awplus(config)#
awplus(config-if)#
If the device is set to send an SNMP trap for those ports, it will continue to do so.
To set the device not to perform any action when it receives reduced power on
port1.0.1 or port1.0.4, except sending a log message, use the commands:
awplus(config)#
awplus(config-if)#
Related
fiber-monitoring sensitivity
commands
show system fiber-monitoring
Command
Version 5.4.8-0.2: continuous parameter added
changes
C613-50631-01 Rev A
interface port1.0.1-port1.0.4
no fiber-monitoring action shutdown
interface port1.0.1-port1.0.4
no fiber-monitoring action
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
335

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ie340-12gpIe340-12gtIe340-20gpIe340l-18gp