U
L
D
NIDIRECTIONAL
INK
ETECTION
-
UDLD TIME MESSAGE
INTERVAL
udld time message-interval
Overview
Use this command to set the UDLD message send interval on all interfaces.
This is the time, in seconds, between UDLD probe messages.
Use the no variant of this command to reset the message send interval to 15
seconds.
udld time message-interval <seconds>
Syntax
no udld time message-interval
Default
The default message send interval is 15 seconds.
Mode
Global Configuration
Example
To change UDLD message sending interval to 30 sec on all interfaces, use the
commands:
awplus#
awplus(config)#
To reset the message sending interval to 15 seconds, use the commands:
awplus#
awplus(config)#
Related
udld enable
commands
udld port
show udld
C613-50631-01 Rev A
(UDLD) C
OMMANDS
Parameter
Description
<seconds>
7-90
Specify the message send interval in seconds.
configure terminal
udld time message-interval 30
configure terminal
no udld time message-interval
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x