IP IRDP MAXADVERTINTERVAL

ip irdp maxadvertinterval
Overview
This command sets the maximum time allowed between sending router
advertisements from the interface. If you change the maxadvertisementinterval
value, also change the lifetime and the minadvertisementinterval to maintain
the following ratios:
You cannot set the maximum advertisement interval below the minimum interval.
If you are lowering the maximum interval to a value below the current minimum
interval, you must change the minimum value first.
The no variant of this command sets the maxadvertinterval back to the default of
600 seconds.
ip irdp maxadvertinterval <4-1800>
Syntax
no ip irdp maxadvertinterval
Default
The IRDP maximum advertisement interval is set to 600 seconds (10 minutes) by
default.
Mode
Interface Configuration for a VLAN interface or a local loopback interface.
To set the maximum interval between Router Discovery advertisements on vlan7
Examples
to 950 seconds, use the following commands:
awplus#
awplus(config)#
awplus(config-if)#
To set the maximum interval between advertisements on vlan7 back to the
default, use the following commands:
awplus#
awplus(config)#
awplus(config-if)#
C613-50631-01 Rev A
C
OMMANDS
lifetime=3 x maxadvertisementinterval
minadvertisementinterval=0.75 x maxadvertisementinterval
Parameter
Description
<4-1800>
The maximum time, in seconds, between Router Discovery
advertisements.
configure terminal
interface vlan7
configure terminal
interface vlan7
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ip irdp maxadvertinterval 950
no ip irdp maxadvertinterval
891