Download Print this page

Allied Telesis IE340 Series Command Reference Manual page 833

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
SHOW POWER
INLINE INTERFACE
Table 3: Parameters in show power-inline interface output
C613-50631-01 Rev A
Parameter
Description
Interface
The PoE port(s) in the format port1.0.z, where z is the port
number.
After the port number, "/D" indicates the data pair and "/S"
indicates the spare pair (for ports that support high-power PoE).
Admin
The administrative state of PoE on a PoE port, either Enabled or
Disabled.
Pri
The current PoE priorities for PoE ports on the PSE, as configured
from a
• Low displays when the low parameter is issued. The lowest
• High displays when the high parameter is issued. The
• Crit displays when the critical parameter is issued. The
Oper
The current PoE port state when this command was issued:
• Powered displays if there is a PD connected and power is
• Denied displays if supplying power would make the switch
• Off displays if the port is not supplying power but has not
• Disabled displays if the PoE port is administratively disabled.
• Syncing displays if PoE is still initializing the port when you
• Fault displays if there is a problem with PoE on the port.
• Unknown displays if PoE cannot determine the state of the
Power
The power consumption in milliwatts (mW) for the PoE port
when this command was entered.
Device
The description of the connected PD device if a description has
been added with the
description is shown for PDs not configured with the
power-inline description
Class
The class of the connected PD, if power is being supplied to the
PD from the PSE.
See the
further information about power classes.
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
power-inline priority
priority for a PoE enabled port (default).
second highest priority for a PoE enabled port.
highest priority for a PoE enabled port.
being supplied.
go over the power budget. It also displays if the switch is
overheating and therefore has stopped supplying power to
the port.
been denied power by the switch. This is the default state for
ports that are not connected to a PD.
issue the command.
port.
power-inline description
command.
PoE Feature Overview and Configuration Guide