alarm facility link-down relay

Overview
Use this command to trigger an alarm relay if a link goes down on a particular
switch port or ports.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
alarm facility link-down <port-list> relay
Syntax
no alarm facility link-down <port-list> relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility link-down
Example
To trigger the alarm relay if port1.0.2 goes down, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility link-down led
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches.
changes
Also, SNMP traps no longer required.
C613-50631-01 Rev A
Parameter
<port-list>
led.
configure terminal
alarm facility link-down port1.0.2 relay
configure terminal
no alarm facility link-down port1.0.2 relay
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The port or ports to monitor with this alarm. The port
list can be:
• a switchport (e.g. port1.0.4)
• a continuous range of ports separated by a hyphen
(e.g. port1.0.1-1.0.4)
• a comma-separated list (e.g.
port1.0.1,port1.0.3-1.0.4).