Download Print this page

Allied Telesis IE340 Series Command Reference Manual page 343

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

P
C
C
LUGGABLES AND
ABLING
OMMANDS
-
SHOW SYSTEM FIBER
MONITORING
Table 8-1: Parameters in the output from show system fiber-monitoring
Related
debug fiber-monitoring
commands
fiber-monitoring action
fiber-monitoring baseline
fiber-monitoring enable
C613-50631-01 Rev A
Parameter
Reading units
Status
Supported
Debugging
Interval
Sensitivity
Baseline type
Status
Baseline value
Alarm threshold
Alarm
Last 12 readings
Minimum reading
Maximum reading
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The units for optical power readings in the rest of the
display, e.g. 0.0001mW.
Whether active fiber monitoring is enabled or disabled for
this port.
Whether the pluggable inserted in this port supports
active fiber monitoring.
Whether debugging of active fiber monitoring is enabled
or disabled for this port.
The configured interval between readings of optical
power on this port.
The configured sensitivity threshold for optical power
changes on this port.
How the baseline optical power level is calculated: either
the average of the specified number of previous readings
or a specified fixed value in 0.0001mW.
Current values for the following parameters.
The baseline value, calculated according to the configured
baseline method, in 0.0001mW.
The current threshold for a change in optical power,
calculated according to the configured sensitivity method,
that will result in action.
Whether the optical power at the most recent reading
fallen below the threshold.
The last 12 optical power values measured, in 0.0001mW,
with oldest value first.
The lowest optical power reading since the fiber
pluggable was last inserted, or since active fiber
monitoring was last enabled on the port.
The highest optical power reading since the fiber
pluggable was last inserted, or since active fiber
monitoring was last enabled on the port.