ALARM FACILITY EPSR LED

alarm facility epsr led
Overview
Use this command to make the fault LED flash if EPSR detects that a link has gone
down.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility epsr led
no alarm facility epsr led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if EPSR detects that a link has gone down, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility epsr relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50631-01 Rev A
alarm facility epsr
configure terminal
alarm facility epsr led
configure terminal
no alarm facility epsr led