A
M
C
LARM
ONITORING
OMMANDS

ALARM FACILITY TEMPERATURE RELAY

alarm facility temperature relay
Overview
Use this command to make the fault LED flash if the switch's temperature exceeds
the high limit for any of its monitored temperature thresholds.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
To see the limits, use the command
Use the no variant of this command to remove this alarm.
Syntax
alarm facility temperature relay
no alarm facility temperature relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility temperature
Example
To trigger the alarm relay if the switch overheats, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility temperature led
commands
show alarm facility settings
show alarm facility status
show system environment
Command
Version 5.4.9-1.1: input-member and output-member parameters added on
changes
IE510-28GSX switches
C613-50631-01 Rev A
led.
configure terminal
alarm facility temperature relay
configure terminal
no alarm facility temperature relay
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
show system
environment.
alarm
551

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ie340-12gpIe340-12gtIe340-20gpIe340l-18gp