Download Print this page

Gvrp Timer - Allied Telesis IE340 Series Command Reference Manual

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

GVRP C
OMMANDS

GVRP TIMER

gvrp timer
Overview
Use this command to set GVRP timers in Interface Configuration mode for a given
interface.
Use the no variant of this command to reset the GVRP timers to the defaults
specified in the table below.
Syntax
gvrp timer {join <timer-value>|leave <timer-value>|leaveall
<timer-value>}
no gvrp timer {join|leave|leaveall}
Mode
Interface Configuration
Defaults
The default join time value is 20 centiseconds (200 milliseconds), the default leave
timer value is 60 centiseconds (600 milliseconds), and the default leaveall timer
value is 1000 centiseconds (10,000 milliseconds).
When configuring the leave timer, set it to more than or equal to three times the
Usage notes
join timer value. The settings for the leave and join timers must be the same
for all GVRP enabled switches. See also the section "Setting the GVRP Timers" in the
GVRP Feature Overview and Configuration
Use the
Examples
To set the GVRP join timer to 30 hundredths of a second (300 milliseconds) for
interface port1.0.1, enter the commands:
awplus#
awplus(config)#
awplus(config-if)#
To set the GVRP leave timer to 90 hundredths of a second (900 milliseconds) for
interface port1.0.1, enter the commands:
awplus#
awplus(config)#
awplus(config-if)#
C613-50631-01 Rev A
Parameter
Description
join
Specifies the timer for joining the group (default is 20
centiseconds / hundredths of a second, or 200 milliseconds).
leave
Specifies the timer for leaving a group (default is 60 centiseconds /
hundredths of a second, or 600 milliseconds).
leaveall
Specifies the timer for leaving all groups (default is 1000
centiseconds / hundredths of a second, or 10,000 milliseconds).
<timer-value> <1-65535> The timer value in hundredths of a second
(centiseconds).
show gvrp timer
configure terminal
interface port1.0.1
configure terminal
interface port1.0.1
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Guide.
command to confirm GVRP timers set with this command.
gvrp timer join 30
gvrp timer leave 90
846