Download Print this page

Alarm Facility Pse-Port Relay - Allied Telesis IE340 Series Command Reference Manual

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

A
M
C
LARM
ONITORING
OMMANDS
-
ALARM FACILITY PSE
PORT RELAY

alarm facility pse-port relay

Overview
Use this command to trigger an alarm relay if a PoE device plugged into a port is
consuming more than the maximum power output permitted for that port.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
This alarm only triggers if the port exceeds the maximum power output permitted
for that port. It does not trigger if you have configured a lower power budget for
that port and the port exceeds your configured budget.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility pse-port <port-list> relay
no alarm facility pse-port <port-list> relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility pse-port
Example
To trigger the alarm relay if a PoE device plugged into port1.0.2 is consuming more
than the maximum power output permitted for port1.0.2, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility pse-port led
commands
show alarm facility settings
show alarm facility status
C613-50631-01 Rev A
Parameter
<port-list>
led.
configure terminal
alarm facility pse-port port1.0.2 relay
configure terminal
no alarm facility pse-port port1.0.2 relay
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The port or ports to monitor with this alarm. The port
list can be:
• a switchport (e.g. port1.0.4)
• a continuous range of ports separated by a hyphen
(e.g. port1.0.1-1.0.4)
• a comma-separated list (e.g.
port1.0.1,port1.0.3-1.0.4).
alarm
548

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ie340-12gpIe340-12gtIe340-20gpIe340l-18gp