Download Print this page

Timers (Ipv6 Ripng) - Allied Telesis IE340 Series Command Reference Manual

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

RIP
IP
6 C
NG FOR
V
OMMANDS
(IP
6 RIP
)
TIMERS
V
NG

timers (IPv6 RIPng)

Overview
Use this command to adjust the RIPng routing network timers.
Use the no variant of this command to restore the defaults.
Syntax
timers basic <update> <timeout> <garbage>
no timers basic
Default
The default RIPng routing table update timer default is 30 seconds, the default
RIPng routing information timeout timer is 180 seconds, and the default RIPng
routing garbage collection timer is 120 seconds. The no variant of this command
restores the default RIPng routing timers.
Mode
Router Configuration
Example
To adjust the RIPng routing network timers, use the following commands:
awplus#
awplus(config)#
awplus(config-router)#
C613-50631-01 Rev A
Parameter
Description
<update>
<5-2147483647> Specifies the RIPng routing table update timer in
seconds. The default is 30 seconds.
<timeout>
<5-2147483647> Specifies the RIPng routing information timeout
timer in seconds. The default is 180 seconds. After this interval has
elapsed and no updates for a route are received, the route is declared
invalid.
<garbage>
<5-2147483647> Specifies the RIPng routing garbage collection
timer in seconds. The default is 120 seconds.
configure terminal
router ipv6 rip
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
timers basic 30 180 120
1100

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ie340-12gpIe340-12gtIe340-20gpIe340l-18gp