Alarm Facility Ufo Relay - Allied Telesis IE340 Series Command Reference Manual

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

A
M
C
LARM
ONITORING
OMMANDS

ALARM FACILITY UFO RELAY

alarm facility ufo relay
Overview
Use this command to trigger an alarm relay if one or more UFO VLANs are isolated
and cannot forward traffic.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
alarm facility ufo relay
Syntax
no alarm facility ufo relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility ufo
Example
To trigger the alarm relay if one or more UFO VLANs are isolated and cannot
forward traffic, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility ufo led
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50631-01 Rev A
led.
configure terminal
alarm facility ufo relay
configure terminal
no alarm facility ufo relay
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
alarm
553