C
F
M
ONNECTIVITY
AULT
ANAGEMENT
SHOW ETHERNET CFM MAINTENANCE
Figure 9-7:
Table 9-5: Parameters in the output from show ethernet cfm
C613-50631-01 Rev A
C
OMMANDS
-
POINTS LOCAL MEP
Example output from show ethernet cfm maintenance-points
local mep domain MD-INST1 service MA-INST1-1 mep 12
details
awplus#show ethernet cfm maintenance-points local mep domain
MD-INST1 service MA-INST1-1 mep 12 details
Domain Name....................... MD-INST1
MA Service Name................... MA-INST1-1
MA Primary VLAN................... 0
MEP ID............................ 12
Direction......................... Down
Interface......................... port1.0.2
MEP Active State.............. True
CC State...................... Enabled
CC Type....................... Multicast
PDU VLAN Priority............. 7
MAC-address................... 000c.2526.95a1
Tx-RDI........................ True
Current Defects............... 3 (someRMEPCCMdefect)
Current Highest Defect Alarm.. 4 (someRMEPCCMdefect)
Alarm Minimum Defect.......... 2 (someMACstatusDefect)
Alarm Trip Time............... AUTO (2.5 seconds)
Alarm Reset Time.............. AUTO (10 seconds)
Configured Remote MEPs........ 21
Missing Remote MEPs........... 21
Error CCM Reason.............. N/A
Last Error CCM................ N/A
Cross-connect Defect Reason... N/A
Last Cross Connect CCM........ N/A
maintenance-points local mep domain <domain-name> service
<ma-name> mep <mep-id> details
Parameter
Domain Name and
MA Service Name
MA Primary VLAN
MEP ID
Direction
Interface
MEP Active State
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
Uniquely identify the MD and MA this local MEP is
associated with.
The VLAN used by this MEP. A link-local MEP VLAN is
indicated by "-".
The local MEP's ID.
The direction of the local MEP, either Down or Up.
The Interface port or Interface lag that the local MEP is
configured against.
The MEP's configured administrative state:
Up: True
Down: False.
391