Download Print this page

Alarm Facility Link-Down Led - Allied Telesis IE340 Series Command Reference Manual

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

A
M
C
LARM
ONITORING
OMMANDS
-
ALARM FACILITY LINK
DOWN LED

alarm facility link-down led

Overview
Use this command to make the fault LED flash if a link goes down on a particular
switch port or ports.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility link-down <port-list> led
no alarm facility link-down <port-list> led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if port1.0.2 goes down, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility link-down relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches.
changes
Also, SNMP traps no longer required.
C613-50631-01 Rev A
Parameter
<port-list>
alarm facility link-down
configure terminal
alarm facility link-down port1.0.2 led
configure terminal
no alarm facility link-down port1.0.2 led
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The port or ports to monitor with this alarm. The port
list can be:
• a switchport (e.g. port1.0.4)
• a continuous range of ports separated by a hyphen
(e.g. port1.0.1-1.0.4)
• a comma-separated list (e.g.
port1.0.1,port1.0.3-1.0.4).
relay.
539

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ie340-12gpIe340-12gtIe340-20gpIe340l-18gp