P
C
C
LUGGABLES AND
ABLING
OMMANDS
SHOW SYSTEM PLUGGABLE DIAGNOSTICS
Output
Figure 8-5:
awplus#show system pluggable diagnostics
System Pluggable Information Diagnostics
port1.0.1
Temp: (Degrees C)
Vcc: (Volts)
Tx Bias: (mA)
Tx Power: (mW)
Rx Power: (mW)
Rx LOS:
...
Table 9: Parameters in the output from the show system pluggables
Related
show system environment
commands
show system pluggable
show system pluggable detail
C613-50631-01 Rev A
Example output from the show system pluggable diagnostics
command on a device
Status
Reading
Alarm
44.871
-
100.00
3.3043
-
3.4650
3.468
-
13.264
0.2376
-
0.7943
0.2104
-
1.0000
Rx Up
diagnostics command
Parameter
Temp (Degrees C)
Vcc (Volts)
Tx Bias (mA)
Tx Power (mW)
Rx Power (mW)
Rx LOS
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Alarms
Max
Min
Warning
-40.00
3.1350
0.000
0.0562
0.0126
Description
Shows the temperature inside the transceiver.
Shows voltage supplied to the transceiver.
Shows current to the Laser Diode in the transceiver.
Shows the amount of light transmitted from the transceiver.
Shows the amount of light received in the transceiver.
Rx Loss of Signal. This indicates whether:
• light is being received (Rx Up) and therefore the link is up,
or
• light is not being received (Rx Down) and therefore the
link is down
Warnings
Min 
Max
-
95.000
-30.00
-
3.4000
3.2000
-
10.264
0.264
-
0.6310
0.0708
-
0.7943
0.0200