A
M
C
LARM
ONITORING
OMMANDS
ALARM FACILITY UFO LED
alarm facility ufo led
Overview
Use this command to make the fault LED flash if one or more UFO VLANs are
isolated and cannot forward traffic.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility ufo led
no alarm facility ufo led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if one or more UFO VLANs are isolated and cannot forward traffic,
use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility ufo relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50631-01 Rev A
alarm facility ufo
configure terminal
alarm facility ufo led
configure terminal
no alarm facility ufo led
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
relay.
552