ALARM FACILITY UFO LED

alarm facility ufo led
Overview
Use this command to make the fault LED flash if one or more UFO VLANs are
isolated and cannot forward traffic.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility ufo led
no alarm facility ufo led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if one or more UFO VLANs are isolated and cannot forward traffic,
use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#