P
E
C
OWER OVER
THERNET
OMMANDS
-
SHOW POWER
INLINE INTERFACE DETAIL
Table 4: Parameters in show power-inline interface detail output
C613-50631-01 Rev A
Parameter
Description
Interface
The PoE port(s) in the format portx.y.z, where x is the device
number, y is the module number within the device, and z is the
PoE port number within the module.
Powered
The name of the PD, if connected and if power is being supplied
device type:
to the PD from the PSE, configured with the
description
configured for the PD.
PoE admin
The administrative state of PoE on a PoE capable port, either
Enabled or Disabled as configured from the
command or the no power-inline enable command
respectively.
Priority
The PoE priority of a port, which is either Low, or High, or
Critical, as configured by the
Detection
The current PSE PoE port state when this command was issued:
status:
• Powered displays when there is a PD connected and power is
• Denied displays when supplying power would make the PSE
• Disabled displays when the PoE port is administratively
• Off displays when PoE has been disabled for the port.
• Fault displays when a PSE goes over its power allocation.
High
Whether HANP is enabled or disabled on the port. HANP is also
Availability
known as Continuous PoE. It enables the switch to perform
Network
actions such as software upgrades without forcing the Powered
Power:
Devices to power cycle. This allows, for example, IP cameras to
buffer data instead of losing it. Note that this information is only
displayed if Continuous PoE is enabled globally on the switch.
Current power
The power consumption for the PoE port when this command
consumption:
was entered. Note that the power consumption may have
changed since the command was entered and the power is
displayed.
Powered
The class of the connected PD if connected, and if power is being
device class:
supplied to the PD from the PSE.
See the
further information about power classes.
Power
The power in milliwatts (mW) allocated for the PoE port.
allocated
Additionally, note the following as displayed per PoE port:
• [U] if the power limit for a port was user configured (with the
• [L] if the power limit for a port was supplied by LLDP.
• [C] if the power limit for a port was supplied by the PD class.
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
command. n/a displays if a description has not been
being supplied from the PSE.
go over the power budget.
disabled.
PoE Feature Overview and Configuration Guide
power-inline max command).
power-inline
power-inline enable
power-inline priority
command.
for