Overview
Use this command to trigger an alarm relay if one or more G.8032 ERP instances are
in the PROTECTION state.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
alarm facility g8032 relay
Syntax
no alarm facility g8032 relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility g8032
Example
To trigger the alarm relay if one or more G.8032 ERP instances are in the
PROTECTION state, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility g8032 led
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50631-01 Rev A
led.
configure terminal
alarm facility g8032 relay
configure terminal
no alarm facility g8032 relay
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
alarm
533

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ie340-12gpIe340-12gtIe340-20gpIe340l-18gp