MONITORING INTERFACE

clear fiber-monitoring interface

Overview
Use this command to clear the Active Fiber Monitoring state of a port. It clears the
alarm, baseline and history and starts monitoring from the beginning. It does not
change the configuration.
clear fiber-monitoring interface <port>
Syntax
Default
n/a
Mode
Privileged Exec
Usage notes
Normally, you do not need to clear the Active Fiber Monitoring state of a port. If the
issue resolves itself and the monitored optical power returns to the baseline, the
alarm clears automatically.
However, you may need to clear the Active Fiber Monitoring state if the optical
power level reduces for a known reason, causing the port to be stuck in the alarm
state. In this situation, the alarm will not clear automatically, because Active Fiber
Monitoring does not update the baseline when the port is in the alarm state, for
security reasons.
Example
To clear the Active Fiber Monitoring state for interface port1.0.1, use the
command:
awplus#
Related
show system fiber-monitoring
commands
Command
Version 5.4.8-0.2: command added
changes
C613-50631-01 Rev A
Parameter
Description
<port>
The name of the port to reset Active Fiber Monitoring on.
clear fiber-monitoring interface port1.0.1