fiber-monitoring interval

Overview
Use this command to configure the fiber monitoring polling interval in seconds for
the port. The optical power will be read every <interval> seconds and compared
against the calculated threshold values to see if a log message or other action is
required.
Use the no variant of this command to reset the polling interval to the default (5
seconds).
fiber-monitoring interval <2-60>
Syntax
no fiber-monitoring interval
Default
The interval is set to 5 seconds by default.
Mode
Interface configuration mode for a fiber port.
Example
To set the fiber monitoring polling interval for port 1.0.2 to 30 seconds, use the
commands:
awplus(config)#
awplus(config-if)#
To reset the fiber monitoring polling interval back to the default (5s), use the
commands:
awplus(config)#
awplus(config-if)#
Related
fiber-monitoring baseline
Commands
show system fiber-monitoring
C613-50102-01 REV C
Parameter
Description
<2-60>
Optical power polling interval in seconds.
interface port1.0.2
interface port1.0.2
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
fiber-monitoring interval 30
no fiber-monitoring interval