Siemens SINAMICS S110 List Manual page 55

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r0102[0...1]
Number of drive objects / DO count
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Topology
Not for motor type: -
Min
-
Description:
Displays the number of existing or existing and prepared drive objects.
Index:
[0] = Existing drive objects
[1] = Existing and prepared drive objects
Dependency:
Refer to: p0101
Note:
The numbers of the drive objects are in p0101.
Index 0:
Displays the number of drive objects that have already been set up.
Index 1:
Displays the number of drive objects that have already been set up and, in addition, the drive objects that still have
to be set up.
p0108[0...23]
Drive object, function module / DO function module
CU_S110-CAN,
Can be changed: C1(2)
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
The function module of an existing drive object is entered into each index (see p0101, p0107).
The following bits are available for the Control Unit (Index 0):
Bit 18: Free function blocks
Bit 29: CAN
Bit 30: COMM BOARD
Bit 31: PROFINET
For all other drive objects (Index > 0), the significance of the bits should be taken from the display parameters r0108
of the drive object.
Index:
[0] = Function module Control Unit
[1] = Function module object 1
[2] = Function module object 2
[3] = Function module object 3
[4] = Function module object 4
[5] = Function module object 5
[6] = Function module object 6
[7] = Function module object 7
[8] = Function module object 8
[9] = Function module object 9
[10] = Function module object 10
[11] = Function module object 11
[12] = Function module object 12
[13] = Function module object 13
[14] = Function module object 14
[15] = Function module object 15
[16] = Function module object 16
[17] = Function module object 17
[18] = Function module object 18
[19] = Function module object 19
[20] = Function module object 20
[21] = Function module object 21
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin