ABB IRB 460 Series Product Manual page 88

Table of Contents

Advertisement

2 Installation and commissioning
2.4.1 Option 87-1 - Installing the cooling fan for axis-1 motor
Continued
Illustration of separate cable for the fan
The figure below shows the cabling used for the fan on axis 1.
xx1300000765
A
B
C
Installing the separate cable for the fan
1
2
3
Continues on next page
88
Connector R3.FAN.
Connected to the fan box.
Connector R2.FAN.
Connected to the robot cable harness.
Screw M12x1.5.
Secures the cable to the motor cover.
Action
Move the robot to its calibration position.
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Insert the fan cable through the motor cover and
tighten the screw.
© Copyright 2012-2018 ABB. All rights reserved.
Note
xx1300000766
Product manual - IRB 460
3HAC039842-001 Revision: P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 460-110/2.4

Table of Contents