3 Maintenance
3.3.7 Inspecting the additional mechanical stops
Continued
Inspecting, mechanical stops
Use this procedure to inspect the additional mechanical stops.
1
2
3
4
116
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
Make sure no additional stops are damaged.
Make sure the stops are properly attached.
Correct tightening torque, additional mechanical
stops:
Axis 1 = 120 Nm.
If any damage is detected, the mechanical stops must
be replaced.
Correct attachment screws:
Axis 1: M12 x 40, quality 12.9.