set cdp auth

set cdp auth
Use this command to set a global CDP authentication code.
Syntax
set cdp auth auth-code
Parameters
auth-code
Defaults
None.
Mode
Switch command, read-write.
Usage
The authentication code value determines a switch's CDP domain. If two or more switches have
the same CDP authentication code, they will be entered into each other's CDP neighbor tables. If
they have different authentication codes, they are in different domains and will not be entered
into each other's CDP neighbor tables.
A switch with the default authentication code (16 null characters) will recognize all switches, no
matter what their authentication code, and enter them into its CDP neighbor table.
Example
This example shows how to set the CDP authentication code to 1,2,3,4,5,6,7,8:
C3(su)->set cdp auth 1,2,3,4,5,6,7,8:

set cdp interval

Use this command to set the message interval frequency (in seconds) of the CDP discovery
protocol.
Syntax
set cdp interval frequency
Parameters
frequency
Defaults
None.
Mode
Switch command, read-write.
10-4 Discovery Protocol Configuration
Specifies an authentication code for the CDP protocol. This can be up to 16
hexadecimal values separated by commas.
Specifies the transmit frequency of CDP messages in seconds.Valid values