Download Print this page

Oki ES9160 Maintenance Manual page 994

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Process
Separation
mode
08
Setting
Process
Developer
mode
08
Setting
Process
Process
mode
08
Setting
Scanner
Scanner
mode
Item
Subitem
Code
2966
2978
2987
3015
Sub-
Default
Acceptable
Details
code
value
value
2
Thin paper separation
Refer to
0~255
trailing edge output
content
correction (L)
s
Switching of
0
0-8
correction of
development contrast
life
Transfer bias output
Refer to
0~255
correction between
content
sheets of paper
s
Pre-scan setting
0
0~1
switchover
17
RAM
Contents
M
<Default value>
148
M
If the image density is too dark after unpacking,
replacing EPU or developer material, the image density
becomes lighter by changing this setting during the
initial use of the developer material.
Since the image density becomes too light depending
on the setting, be sure to check the image after
changing the setting.
The image density does not change after the correction
period ends. Note that the image density may become
too light as the time of use passes if the correction
period is set to "long." Once this setting is changed, the
correction is enabled after replacing EPU or developer
material. Be sure to check the image density after the
replacement.
0: No correction
1: Correction amount – small (-30v), correction length -
short (0 to 0.7k sheets) 2: Correction amount – medium
(-60v), Correction length - short (0 to 5k sheets) 3:
Correction amount – large (-90v), correction length -
middle (0 to 11k sheets) 4: Correction amount – small
(-30v), correction length - middle (0 to 5k sheets) 5:
Correction amount – medium (-60v), correction length -
long (0 to 12k sheets)
6: Correction amount – large (-90v), correction length
- long (0 to 13k sheets)
7: Correction amount – medium (-60v), correction
length
- middle (0 to 10k sheets)
8: Correction amount – large (-85v), correction length
- short (0 to 7k sheets)
M
The transfer cleaning bias is output between sheets of
paper during printing so as to prevent the toner on the
photoconductive drum from adhering to the transfer
roller. This code is used to correct the output between
sheets of paper to that adjusted in 05-2084 (Transfer
cleaning bias adjustment (negative)). The larger the
setting value is, the higher the value of the current
(more negative) is. Note that toner with a different
polarity will adhere easily if the setting value is too large
or too small.
<Default value>
104
SYS 0: Not performing pre-scanning 1: Performing pre-
scanning
Proce
Servic
dure
e UI
4
1
1
1
Yes

Advertisement

loading

This manual is also suitable for:

Es9170