Installation, fan on motor axis 1
Use this procedure to install the cooling fan on motor axis 1.
1
2
3
4
5
6
7
Product manual - IRB 4600
3HAC033453-001 Revision: Y
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Remove the back plate of the fanbox.
Place the fanbox around motor axis 1.
Refit the back plate of the fanbox.
Tip
If there is a lack of space between motor and
robot, it is possible to remove part of the fanbox.
Push the fanbox in line with the connection box.
Fit the fanbox with two attachment screws
M6x25.
© Copyright 2009-2021 ABB. All rights reserved.
2 Installation and commissioning
2.5.1 Installation of cooling fan for motors (option)
Note
See the figure in:
See the figure in:
See the figure in:
Align the upper part of the fan with the
lower part of the connection box.
A
xx1000000124
Parts:
Continued
Cooling fan on page 83
Cooling fan on page 83
Cooling fan on page 83
B C
A: Connection box
B: Position where the fan shall
be aligned with connection box
C: Fan
Continues on next page