4 Repair
4.8.3 Replacing gearbox axis 3
Continued
Equipment
Other tools and procedures may be
required. See references to these
procedures in the step-by-step in-
structions below.
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Removing gearbox axis 3
Use this procedure to remove the gearbox.
1
2
Continues on next page
328
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
WARNING
The procedure details how to replace the gearbox without removing the cable
harness. This means that the upper and lower arm will be separated but still be
connected to eachother through the cabling. Be careful not to damage the cables!
Action
Decide which calibration routine to use, and
take actions accordingly prior to beginning
the repair procedure.
Drain the gearbox.
© Copyright 2009-2021 ABB. All rights reserved.
Art. no.
Note
These procedures include refer-
ences to the tools required.
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.
Note
How to drain the gearbox is described in
section:
Changing the oil, axis-3 gearbox
on page 163
Reference calibration
349.
Product manual - IRB 4600
3HAC033453-001 Revision: Y