54.2.5 GOT side settings

Setting communication interface
(Communication settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: AB
• Controller Type: Set either of the followings.
• SLC500
• MicroLogix1000/1200/1400/1500 series
• Control/CompactLogix
• I/F: Interface to be used
• Driver: Set either of the followings.
• When connecting to SLC500 Series: AB SLC500,
AB 1:N
• When connecting to MicroLogix1000/1200/1400/
1500 Series: AB MicroLogix
• When connecting to Control/Compact/FlexLogix
Series: AB Control/CompactLogix
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
54.2.5  Communication detail settings
OK
Click the
button when settings are completed.
54 - 10
54. CONNECTION TO ALLEN-BRADLEY PLC
54.2 Serial connection
Click!
[Controller Setting] from the
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
Communication detail settings
3.
(1) AB SLC500, AB 1: N
Item
Transmission
4.
Speed
Adapter
*1
Address
Host
*1
Address
*1
(2) AB MicroLogix
Item
Transmission
Speed
Sum Check
Type
Adapter
*1
Address
Host
*1
Address
*1
18.1.2 I/F communication setting
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
Specify the adapter address (station No. of
the PLC that the GOT will monitor) in the
connected network.
(Default: 0)
Specify the host address (station No. of the
adapter to which the GOT is connected) in
the connected network.
(Default: 1)
Do not specify the same value for the adapter address and
host address.
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
Specify the format in which the sum check
is performed during communication when
performing sum check.
(Default: BCC)
Specify the adapter address (station No. of
the PLC that the GOT will monitor) in the
connected network.
(Default: 0)
Specify the host address (station No. of the
adapter to which the GOT is connected) in
the connected network.
(Default: 1)
Do not specify the same value for the adapter address and
host address.
Range
4800bps,
9600bps,
19200bps
0 to 31
1 to 31
Range
4800bps,
9600bps,
19200bps,
38400bps
BCC, CRC16
0 to 63
1 to 63