54.3 Ethernet Connection

54.3.1 System configuration for connecting to ControlLogix or CompactLogix

ControlLogix,
CompactLogix
PLC
EtherNet/IP
communication
Series
*1
module
*4
1756-ENET
(10Mbps)
*4
1756-ENBT
ControlLogix
(10/100Mbps)
*4
1756-EN2TR
(10/100Mbps)
CompactLogix
-
*1
*2
*3
*4
54 - 12
54. CONNECTION TO ALLEN-BRADLEY PLC
54.3 Ethernet Connection
EtherNet/IP
communication
module
Connection cable
*2
Connection cable
Commun
ication
Cable model
type
• 10BASE-T
Shielded twisted pair
cable (STP)
or
Unshielded twisted
pair cable (UTP)
Ethernet
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair
cable (STP)
Category 5 and 5e
Allen-Bradley product manufactured by Rockwell Automation, Inc. For details of this product, contact Rockwell Automation, Inc.
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
The use of shielded twisted pair cable (STP) is recommended in environments in which the performance against noise is
required.
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
The connectable EtherNet/IP communication module differs depending on the PLC series.
(ControlLogix5550/5555/5560)
1756-ENET(10Mbps), 1756-ENBT(10/100Mbps)
(ControlLogix5570)
1756-EN2TR(10/100Mbps)
Connector
conversion
box
Connector
External cable
conversion box
GT14H-C30-42P (3m)
GT16H-CNB-42S
GT14H-C60-42P (6m)
GT14H-C100-42P (10m)
GT11H-C30-37P (3m)
GT16H-CNB-37S
GT11H-C60-37P (6m)
GT11H-C100-37P (10m)
GT14H-C30-42P (3m)
GT16H-CNB-42S
GT14H-C60-42P (6m)
GT14H-C100-42P (10m)
GT11H-C30-37P (3m)
GT16H-CNB-37S
GT11H-C60-37P (6m)
GT11H-C100-37P (10m)
Communication driver
Ethernet/IP(AB), Gateway
GOT
External cable
Maximum
GOT
Number of connectable
*6
segment
model
*3
length
100m
When PLC:GOT is N:1
The following shows the
number of PLCs for 1
GOT
TCP: 128 or less
100m
When PLC:GOT is 1:N
The following shows the
number of GOTs for 1
PLC
TCP: 32 or less
(recommended to 16
units or less)
(Continued to next page)
equipment
*5

Advertisement

Table of Contents
loading

Table of Contents