Connecting To Rb Series; Connecting To Pf900; Connecting To Ha400, Ha900; Connecting To Ag500 - Mitsubishi Electric GT14 User Manual

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

53.5.7 Connecting to RB Series

Communication settings
Item
Communication protocol
1: MODBUS
Device address
1 to 99
*1
(Slave address)
2: 9600bps
*2
Communication speed
3: 19200bps
Data bit configuration
Refer to  Data bit configuration.
Interval time
0 to 250
*1
When the setting value is set to 0, a communication is not
made.
*2
Adjust the settings with GOT settings.
Data bit configuration
Set value
Data bit
0
8
1
8
2
8
3
8
4
8
5
8
Communication setting mode
Set the communication setting mode using the
operation panel of the RB series main unit.
For details of the communication setting mode, refer to
the following.
RB series "Communication Instruction Manual"

53.5.8 Connecting to PF900

Communication settings
Make the communication settings by operating the key
of the temperature controller.
Item
*1
9600bps, 19200bps, 38400bps, 57600bps
Communication speed 1
Communication protocol 1
MODBUS
[8N1]: 8bits, None, 1bit
[8N2]: 8bits, None, 2bits
*1
[8E1]: 8bits, Even, 1bit
Data bit configuration 1
[8E2]: 8bits, Even, 2bits
(Data bit, Parity bit, Stop bit)
[8O1]: 8bits, Odd, 1bit
[8O2]: 8bits, Odd, 2bits
*2
Device address 1
1 to 99
(Slave address 1)
*3
0 to 250 (ms)
Interval time
*1
Adjust the settings with GOT settings.
*2
Select the device address 1 without overlapping with that of
other units.
*3
Set the maximum time from the sending of the last character
stop bit from the GOT side until the switching of the GOT
side to the receiving status (until the temperature controller
becomes ready to send). Set as necessary.
*4
When the setting value is set to 0, a communication is not
made.
Setting range
Parity bit
Stop Bit
None
1
None
2
Even
1
Even
2
Odd
1
Odd
2
Setting range
*4
53. CONNECTION TO RKC TEMPERATURE CONTROLLER

53.5.9 Connecting to HA400, HA900

Communication settings
Make the communication settings by operating the key
of the temperature controller.
(Communication 1)
Item
*1
9600bps, 19200bps, 38400bps
Communication speed 1
[8N1]: 8bits, None, 1bit
[8N2]: 8bits, None, 2bits
*1
[8E1]: 8bits, Even, 1bit
Data bit configuration 1
[8E2]: 8bits, Even, 2bits
(Data bit, Parity bit, Stop bit)
[8O1]: 8bits, Odd, 1bit
[8O2]: 8bits, Odd, 2bits
*2
Device address 1
1 to 99
(Slave address 1)
*3
0 to 250 (ms)
Interval time
(Communication 2)
Item
*1
9600bps, 19200bps, 38400bps
Communication speed 2
[8N1]: 8bits, None, 1bit
[8N2]: 8bits, None, 2bits
*1
[8E1]: 8bits, Even, 1bit
Data bit configuration 2
[8E2]: 8bits, Even, 2bits
(Data bit, Parity bit, Stop bit)
[8O1]: 8bits, Odd, 1bit
[8O2]: 8bits, Odd, 2bits
*2
Device address 2
1 to 99
(Slave address 2)
*3
0 to 250 (ms)
Interval time
*1
Adjust the settings with GOT settings.
*2
Select the device address 1 and 2 without overlapping with
that of other units.
*3
Set the maximum time from the sending of the last character
stop bit from the GOT side until the switching of the GOT
side to the receiving status (until the temperature controller
becomes ready to send). Set as necessary.
*4
When the setting value is set to 0, a communication is not
made.

53.5.10 Connecting to AG500

Communication settings
Make the communication settings by operating the key
of the temperature controller.
Item
*1
9600bps, 19200bps, 38400bps
Communication speed
Communication protocol
MODBUS
[8N1]: 8bits, None, 1bit
[8N2]: 8bits, None, 2bits
*1
[8E1]: 8bits, Even, 1bit
Data bit configuration
[8E2]: 8bits, Even, 2bits
(Data bit, Parity bit, Stop bit)
[8O1]: 8bits, Odd, 1bit
[8O2]: 8bits, Odd, 2bits
*2
Device address
1 to 99
(Slave address)
*3
0 to 250 (ms)
Interval time
*1
Adjust the settings with GOT settings.
*2
Select the device address 1 without overlapping with that of
other units.
*3
Set the maximum time from the sending of the last character
stop bit from the GOT side until the switching of the GOT
side to the receiving status (until the temperature controller
becomes ready to send). Set as necessary.
*4
When the setting value is set to 0, a communication is not
made.
53.5 Temperature Controller Side Setting
Setting range
*4
Setting range
*4
Setting range
*4
53 - 43
48
49
50
51
52
53
54
55