L Devices; M Devices - Mitsubishi Electric GT14 User Manual

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

61.4.3 L devices

The L devices are bit devices into which user data are stored.
All of these devices can be used as a user area.
List of L devices and differences in address specification by data format
The following shows the L devices (virtual devices inside the GOT).
The address specification values different depending on the data format are also given below.
Address
b7
b6
b5
b4
L7
L6
L5
L4
L15
L14
L13
L12
L23
L22
L21
L20
L31
L30
L29
L28
L2039
L2038
L2037
L2036
L2047
L2046
L2045
L2044
*1
*2

61.4.4 M devices

The M devices are bit devices into which user data are stored.
All of these devices can be used as a user area.
List of M devices and differences in address specification by data format
The following shows the M devices (virtual devices inside the GOT).
The address specification values different depending on the data format are also given below.
b7
b6
b5
b4
M7
M6
M5
M4
M15
M14
M13
M12
M23
M22
M21
M20
M31
M30
M29
M28
M2039 M2038 M2037 M2036 M2035 M2034 M2033 M2032
M2047 M2046 M2045 M2044 M2043 M2042 M2041 M2040
*1
*2
61 - 12
61. MICROCOMPUTER CONNECTION (SERIAL)
61.4 Device Data Area
b3
b2
b1
b0
L3
L2
L1
L0
L11
L10
L9
L8
L19
L18
L17
L16
L27
L26
L25
L24
L2035
L2034
L2033
L2032
L2043
L2042
L2041
L2040
For the address specification method for each data format, refer to the following.
61.5 Message Formats
• Formats 1, 2
: GOT-A900 Series microcomputer connection
• Formats 3 to 6
: A compatible 1C frame
• Formats 7 to 10 : QnA compatible 3C/4C frame
• Formats 11 to 13 : Digital Electronics Corporation's memory link method
• Formats 14, 15
: GOT-F900 Series microcomputer connection
For reading or writing data in word units, specify the addresses in 16-point units. (Example: L0, L16, L32, etc.)
Address
b3
b2
b1
M3
M2
M1
M11
M10
M9
M19
M18
M17
M27
M26
M25
For the address specification method for each data format, refer to the following.
61.5 Message Formats
• Formats 1, 2
: GOT-A900 Series microcomputer connection
• Formats 3 to 6
: A compatible 1C frame
• Formats 7 to 10 : QnA compatible 3C/4C frame
• Formats 11 to 13 : Digital Electronics Corporation's memory link method
• Formats 14, 15
: GOT-F900 Series microcomputer connection
For reading or writing data in word units, specify the addresses in 16-point units. (Example: M0, M16, M32, etc.)
Formats 1, 2
Formats 3 to 6
8192
8193
Same as address column on left
8319
b0
Formats 1, 2
Formats 3 to 6
M0
8320
M8
M16
8321
Same as address column on left
M24
8447
*1
Address specification value
Formats 7 to 10
Formats 11 to 13
2000
2001
*2
207F
*1
Address specification value
Formats 7 to 10
Formats 11 to 13
2080
2081
*2
20FF
Formats 14, 15
A000
H
H
A001
H
A002
H
H
A003
H
A0FE
H
H
A0FF
H
Formats 14, 15
2000
H
H
2001
H
2002
H
H
2003
H
20FE
H
H
20FF
H

Advertisement

Table of Contents
loading

Table of Contents