Hitachi SH7751 Hardware Manual page 453

Superh risc engine
Table of Contents

Advertisement

Power-On Sequence: In order to use synchronous DRAM, mode setting must first be performed
after powering on. To perform synchronous DRAM initialization correctly, the bus state controller
registers must first be set, followed by a write to the synchronous DRAM mode register. In
synchronous DRAM mode register setting, the address signal value at that time is latched by a
 
combination of the
controller provides for value X to be written to the synchronous DRAM mode register by
performing a write to address H'FF900000 + X for area 2 synchronous DRAM, and to address
H'FF940000 + X for area 3 synchronous DRAM. In this operation the data is ignored, but the
mode write is performed as a byte-size access. To set burst read/burst write, CAS latency 1 to 3,
wrap type = sequential, and burst length 4, 8*, supported by the SH7751 Series, arbitrary data is
written by byte-size access to the following addresses.
Bus Width
32
4
32
8*
Note: * SH7751R only
The value set in MCR.MRSET is used to select whether a precharge all banks command or a
mode register setting command is issued. The timing for the precharge all banks command is
shown in figure 13.38(1), and the timing for the mode register setting command in figure 13.38(2).
Before mode register, a 200 µs idle time (depending on the memory manufacturer) must be
guaranteed after the power required for the synchronous DRAM is turned on. If the reset signal
pulse width is greater than this idle time, there is no problem in making the precharge all banks
setting immediately.
First, a precharge all banks (PALL) command is issued in the TRp1 cycle by performing a write to
address H'FF900000 + X or H'FF940000 + X while MCR.MRSET = 0. Next, the number of
dummy auto-refresh cycles specified by the manufacturer (usually 8) or more must be executed.
This is achieved automatically while various kinds of initialization are being performed after auto-
refresh setting, but a way of carrying this out more dependably is to change the RTCOR register
value to set a short refresh request generation interval just while these dummy cycles are being
executed. With simple read or write access, the address counter in the synchronous DRAM used
for auto-refreshing is not initialized, and so the cycle must always be an auto-refresh cycle. After
auto-refreshing has been executed at least the prescribed number of times, a mode register setting
command is issued in the TMw1 cycle by setting MCR.MRSET to 1 and performing a write to
address H'FF900000 + X or H'FF940000 + X.
Rev. 3.0, 04/02, page 414 of 1064
 

,
, and RD/
CAS Latency
1
2
3
1
2
3
signals. If the value to be set is X, the bus state
Area 2
H'FF900048
H'FF900088
H'FF9000C8
H'FF90004C
H'FF90008C
H'FF9000CC
Area 3
H'FF940048
H'FF940088
H'FF9400C8
H'FF94004C
H'FF94008C
H'FF9400CC