Field Service Ver. 1.0 Nov. 2008
6.4

Cleaning procedure

NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
6.4.1

Tray 1 media feed roller

1. Open the top cover.
2. Remove the imaging cartridge.
See P.13
[1]
6.4.2

Printer head window

1. Enter the [P/H CLEAN UP] mode.
For magicolor 1600W: See P.53
For magicolor 1650EN: See P.70
2. Open the top cover.
3. Remove the imaging cartridge.
See P.13
3. Using a cleaning pad dampened with
alcohol, wipe the tray1 media feed
roller [1] clean of dirt.
A034F2C516DA
4. Clean P/H window [1] with soft cloth.
[1]
A034F2C517DA