All manuals and user guides at all-guides.com
03.99
5
Start-up of the CBL
Using two
If two communication boards are used the CB in the lower letter slot is
communication
the first one. The CB in the higher letter slot is the second one.
boards
The CB parameters of the first communication board are reached with
index 1, the second with index 2; e.g. P711.2 is parameter P711 of the
second communication board.
At chapter "softwiring" transmit and receive channel have to be routed
to the setpoint and actual value channels. The connectors of the first
CB have numbers like 3XXX, the second CB like 8XXX.
If two CBs are used refer to the documentation and function diagrams
of the converter and check the connector numbers.
5.1
Basic parameterization of the units
Basic
parameterization for
MASTERDRIVES with
CUMC or CUVC
Fig. 5-1
Siemens AG
6SE7087-6NX84-0GB0
SIMOVERT MASTERDRIVES
Optional boards?
CBL? Yes:
P060 = 4
P711 = 0...4
P712 = 0...255
P715 = typ. 350
P716 = typ. 351
P717 = typ. 352
P718 = typ. 353
P918 = 1...64
P060 = 1
P722 = 0...65535
P053 = x
Go on with
softwiring
Parameterization of the "hardware configuration" for MASTERDRIVES
with CUMC or CUVC
Operating Instructions
Start-up of the CBL
Function selection "hardware configuration"
CB-Parameter for CBL:
Data transmission rate
Option switch
Scaling parameter A
Scaling parameter V
Scaling parameter Hz
Scaling parameter rotation/min
CC-Link station number
Function selection "leave hardware configuration"
Telegram failure time
Parameterization enable CBL
See next chapter
5-1