13.2 Emergency stop input signal connection

c
CAUTION
External emergency stop and the RPB emergency stop button are disabled when
pin 13 and pin 14 are directly shorted to each other on the SAFETY connector.
Make connections to ensure the system including the robot controller will always
operate safely.
A 24 V supply is required to operate MP READY. Supply a 24 V to pins 47 to 50 of
the STD.DIO. As long as the 24 V is supplied to those pins, the "Watch on STD.DIO
DC24V" parameter cannot be set to "INVALID".
Emergency stop input signal connection
RCX240
Internally connected
to P.COM (STD.DIO)
24V
Internally connected
to N.COM (STD.DIO)
Motor power
GND
Motor power
supply circuit
Control power
supply
• The emergency stop button on the RPB is connected to the controller through the SAFETY
connector.
c
CAUTION
Pin 11 of the SAFETY connector, pin 12 of the P.COM SAFETY connector of the STD.
DIO, and N.COM of the STD.DIO are internally connected in the controller.
Do not connect the SAFETY connector and STD.DIO connector to different power
supplies. Doing so may cause malfunction
13. Checking the robot controller operation
RPB connector
13
14
SAFETY
SAFETY
connector
connector (supplied)
2
MP READY
3
E-STOPIN1
4
E-STOPIN2
11
12
13
E-STOP24V
14
E-STOPRDY
supply
relay coil
GND
L
AC 200V
N
L1
AC 200V
N2
Emergency stop button
RPB
Use an external control circuit.
Chapter 3 INSTALLATION
1
2
3
4
5
6
7
8
9
10
3-27