14. "UTILITY" mode

14.2 Enabling/disabling the sequence execution flag

1
To enable or disable execution of sequence programs, proceed as follows.
n
NOTE
The following conditions must be satisfied before executing a sequence program.
1. An object program must be made for sequence execution.
2
2. Sequence execution must be enabled.
3. DI10 (Sequence control) contact point must be closed.
4. Operation must be in "AUTO" mode or "MANUAL" mode.
3
Press
1
Set the sequence execution flag.
2
To enable execution of sequence programs, press
4
To disable execution of sequence programs, press
To enable DO reset during sequence program execution, press
5
6
7
8
9
10
4-314
Chapter 4 OPERATION
(SEQUENC) in "UTILITY" mode.
Enabling/disabling the sequence program
(ENABLE).
(DISABLE).
(RST.DO).