Connecting the motor cables
1
Product manual - IRB 6720
3HAC085697-001 Revision: C
Action
Secure the motor with its attachment screws and
washers.
Use a bits extender to reach the screws.
Disconnect the brake release tool.
Refit the oil plug with a new o-ring.
Perform a leak-down test.
Action
Put the motor cables in place in the open-
ing.
© Copyright 2023 ABB. All rights reserved.
5.7.1 Replacing the axis-1 motor
Note
Hex socket head cap screw:
M10x30 12.9 Gleitmo 603+Geomet
500 (4 pcs)
Bits extender: 3HAC12342-1
Tightening torque: 50 Nm.
xx2200001794
O-ring, G 1/2": 3HAC061327-059
Tightening torque: 24 Nm.
xx2200002147
See
Performing a leak-down test
on page
186.