Inspecting the oil level in axis-3 gearbox
Use this procedure to inspect the oil level in the gearbox.
1
2
3
4
5
Continues on next page
130
Action
Jog the robot into position:
Axis 1: no significance
Axis 2: 0°
Axis 3: +10°
Axis 4: no significance
Axis 5: no significance
Axis 6: no significance
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
Make sure that the oil temperature is +25°C
± 10°C.
WARNING
Handling gearbox oil involves several
safety risks, see
Gearbox lubricants (oil or
grease) on page
30.
Open the oil plug.