ABB OmniCore IRB 6720 Product Manual page 435

Table of Contents

Advertisement

3
4
Position for the floor mounted robot
1
Product manual - IRB 6720
3HAC085697-001 Revision: C
Action
Remove four of the five attachment screws
inside the frame recess, that secure the frame
to the gearbox.
Note
Leave the outermost screw fitted as a safety
precaution.
Remove six of the seven attachment screws
under the balancing device.
Note
Leave the screw closest to the axis-1 motor
fitted.
Action
Turn on the power to the robot temporarily.
© Copyright 2023 ABB. All rights reserved.
5.8.1 Replacing the axis-1 gearbox
Note
xx2200001399
xx2200001401
xx2200001402
Note
Continues on next page
5 Repair
Continued
435