059-326 Heat Roll STS Fail RAP

BSD-ON:
BSD 10.2 Fusing Heat Control (2 of 2)
059-326 The system detected an open circuit of the heat roll thermistor.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Ensure that the fuser is installed correctly.
Check the drawer connector between the fuser and the main unit ( DP612) for damage.
Ensure
P/J416
on the drive PWB is connected correctly.
Procedure
Remove the fuser. Measure the resistance between DJ612S pin 7 and pin 8 (across the heat
roll thermistor). An open circuit is measured.
Y
N
Check the items that follow: connections for open circuits, short circuits or poor contacts:
Between DJ612S pin 8 and
P/J416
Between DJ612S pin 7 and
P/J416
If the wiring is good, install a new drive PWB,
Install a new fuser,
PL 10.05 Item
2.
Status Indicator RAPs
059-326, 059-372
WARNING
pin 4 on the drive PWB.
pin 5 on the drive PWB.
PL 1.10 Item
3.
059-372 Heat Roll NC Sensor Differential Fail RAP
BSD-ON:
BSD 10.2 Fusing Heat Control (2 of 2)
059-372 Abnormal temperature monitor AD value of the heat roll NC sensor was detected 10
consecutive times.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Ensure that the fuser is installed correctly.
3.
Check the drawer connector between the fuser and the main unit ( DP612) for damage.
4.
Check the connections and wiring between the fuser ( DP612) and the drive PWB (
J416) for an open circuit, short circuit or poor contact.
5.
If the fault persists, install new components as necessary:
Fuser,
PL 10.05 Item
Drive PWB,
PL 1.10 Item
6.
After correcting the fault, reset the value of NVM location 744-003 (Differential Amplifica-
tion Error Detection Flag) to 0 (Normal). Switch off, then switch on the machine,
April 2017
2-458
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
2.
3.
P/
GP
10.
Launch Issue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versalink b7030Versalink b7035

Table of Contents