024-367 Decompress Other Fail RAP
BSD-ON:
BSD 3.9 ESS
024-367 Incorrect line synchronization was detected.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Ensure the connectors on the hard disk are securely connected.
3.
Format the hard disk drive, refer to
4.
Reload the software,
GP
4.
5.
Perform the
OF2
Special Boot Modes RAP.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10.
dC355
Hard Disk Diagnostics.
024-368 PCI Error RAP
BSD-ON:
BSD 3.9 ESS
024-368 PCI access error occurred due to a faulty PCI bus.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Ensure the connectors on the hard disk are securely connected.
3.
Format the hard disk drive, refer to
4.
Reload the software,
GP
4.
5.
Perform the
OF2
Special Boot Modes RAP.
April 2017
2-307
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
dC355
Hard Disk Diagnostics.
Status Indicator RAPs
024-367, 024-368