Hcf Docking Interlock Open Rap - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

078-301 HCF Docking interlock Open RAP

BSD-ON:
BSD 1.11 DC Power Distribution - HCF
078-301 HCF1 side out switch open. The HCF and the IOT were undocked.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Check that the HCF and the IOT are correctly docked.
Switch off, then switch on the machine,
Procedure
Refer to the procedure that follows as necessary:
GP 9
How to Check a Switch.
Enter
dC330
code 078-301. Dock then undock the HCF to actuate the HCF1 side out switch.
The display changes.
Y
N
Undock the HCF. Actuate the HCF1 side out switch,
changes.
Y
N
Measure the voltage between
age drops to less than +1VDC when the switch is actuated
Y
N
Check the wiring between:
P/J8
pin 1 on the HCF PWB and
P/J8
pin 2 on the HCF PWB and
If the wiring is good, install a new HCF1 side out switch,
Install a new HCF PWB,
PL 70.60 Item
Check the alignment of the HCF docking base and the IOT.
The fault may be intermittent. Check HCF1 side out switch wiring. If the fault persists, install
new components as necessary:
HCF1 side out switch,
PL 70.60 Item
HCF PWB,
PL 70.60 Item
9.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10.
PL 70.60 Item
8. The
P/J8
pin 2 on the HCF PWB and ground. The
FS003
on the HCF1 side out switch.
FS004
on the HCF1 side out switch.
PL 70.60 Item
9.
8.
077-911, 967, 968 Paper Mismatch RAP
077-911 Paper size mismatch user intervention.
077-967 The paper loaded is different from the specified paper type.
077-968 The paper loaded is different from the specified paper type.
Procedure
Switch off, then switch on the machine,
Y
N
Perform
SCP 5
Final Actions.
Load the specified paper, then rerun the job.
display
volt-
8.
April 2017
2-487
GP
10. The fault persists.
Status Indicator RAPs
078-301, 077-911

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versalink b7030Versalink b7035

Table of Contents